Your energy and CO2 savings, explained
A short guide to the savings figures in your dashboard and reports
When a device is switched off on a schedule, we work out how much energy it would have used had it been left on, and count that as energy saved.
Learning how each device normally behaves
Every socket monitors the power drawn by the device plugged into it. Over time we build a picture of that device: how much power it draws when it is in use, when it is idle or on standby, and how its use varies through the day.
Estimating what it would have used
While a device is switched off, we estimate the power it would have drawn had it stayed on. The estimate is based on how that device behaved just before it was switched off. For example, a monitor left idle overnight would typically sit in standby, so we use its standby power. We keep this estimate conservative: it never exceeds the power the device was actually seen drawing beforehand.
Calculating energy savings
Energy saved (kWh) = estimated power while off (kW) × time switched off (hours)
We add this up minute by minute and report it in half-hour periods, so you can see savings by day, week or month.
Converting energy into CO2
Each unit of electricity from the grid has a carbon cost that changes during the day, depending on how the electricity is generated. We use published carbon intensity figures for the grid, half-hour by half-hour, rather than a single annual average.
CO2 saved (g) = energy saved (kWh) × grid carbon intensity (g CO2/kWh)
This means a kilowatt-hour saved at a time when the grid is high-carbon counts for more CO2 than one saved when it is low-carbon.
A simple example
| Device on standby | 20 W (0.02 kW) |
| Switched off overnight | 12 hours |
| Energy saved | 0.02 x 12 = 0.24 kWh |
| Grid carbon intensity overnight | 150 g CO2/kWh |
| CO2 saved | 0.24 x 150 = 36 g |
Across many devices and every night of the year, these savings add up.
Figures are estimates of avoided consumption based on measured device behaviour. Actual savings depend on how each device is used. Example values are for illustration only.